Waterproofing & protection
Waterproofing & protection
H-501 Steel Savior Passivation Tech | Chloride Barrier for Concrete Cancer
Where salt and water conspire to eat your steel, H-501 fights back with self-healing oxide armor. The "iron bodyguard" your concrete deserves.
Review technical parametersProduct overview
Performance and application overview.
The China Marina Mystery
When 12 high-rises showed rebar corrosion after just 5 years, engineers were baffled – until they cut open a column treated with H-501:
"It's like giving rebar an invisibility cloak against chlorides."
How the Magic Works
1.Smart Film Formation
H-501's ions migrate to rebar surfaces, patching micro-cracks with γ-Fe₂O₃ crystals – think of it as self-healing armor for steel.
2.Chloride Jailing
The film's lattice structure acts like a nano-sieve:
3.Allows O₂ and H₂O passage (for cathodic protection)
4.Blocks Cl⁻ ions (size exclusion effect)
5.Concrete's Secret Weapon
Unlike competitors that weaken mixes, H-501 actually boosts 28-day strength by 9% – probably because it reduces micro-cracking during curing.
Technical parameters
Original product values for technical screening.
Values are reproduced without keyword editing. Final selection must follow the current approved technical data sheet, test method and project conditions.
The source-page headings and values are retained as published. Do not interpret an unlabeled value as a guaranteed minimum.
| Property | Iindicator | Iindicator |
|---|---|---|
| State | - | Powder |
| Corrosion Resistance | Saltwater Immersion | No rust on steel surface |
| — | Saltwater Boiling | No rust on steel surface |
| Concrete Properties | Initial Setting Time (min) | ≥ 45 |
| — | Final Setting Time (h) | ≤ 10 |
| — | Compressive Strength Ratio (7 days) | ≥ 90% |
| — | Compressive Strength Ratio (28 days) | ≥ 100% |
| Recommended Dosage | Mild Corrosion Environment | 1.5–3% (per cubic meter of concrete binder) |
| — | Severe Corrosion Environment | 3–5% (per cubic meter of concrete binder) |
Product usage
Application and installation guidance.
When to Deploy H-501
Pro Tips from Bahrain Port Project
1.Concrete Batching
Add with first 10% of mixing water
Add with first 10% of mixing water
Extends set time by 15-30 mins (plan pours accordingly!)
Extends set time by 15-30 mins (plan pours accordingly!)
2.Never
Mix with calcium chloride accelerators
Mix with calcium chloride accelerators
Use in prestressed concrete without our tech team's nod
Use in prestressed concrete without our tech team's nod
Technical enquiry
Check whether H-501 Steel Savior Passivation Tech | Chloride Barrier for Concrete Cancer matches your project.
Include foundation type, grout geometry and volume, strength ages, flow requirement, temperature, standards, placement distance and equipment.
