Cold-weather wind grout
CBGM Antifreeze Wind Turbine Grout
A low-temperature, high-strength, non-shrink grout system for winter wind-farm construction and sites requiring controlled strength development in sub-zero conditions.
Recommended uses
Where this material fits.
- Winter installation of onshore wind turbines
- Cold-region baseplate and anchor cage grouting
- High-altitude and severe-climate wind farms
- Projects requiring temperature-specific method statements
Performance benefits
What the system is designed to deliver.
- Designed for low-temperature construction planning
- High early strength and pumpable placement
- Micro-expansion and frost durability
- Project-specific material and curing temperature controls
Technical data
Requirements and reported values, separated.
“Requirement” is the stated acceptance threshold or range. “Actual result”, “typical value” and “published value” are not guaranteed minima unless the requirement column says so. Final acceptance must follow the approved TDS, report, test method and project conditions.
| Property | Minimum / specified requirement | Typical / reported value | Test method / source |
|---|---|---|---|
| Flowability at −5°C — initial | ≥300 mm | — | ZRETE CBGM Antifreeze product data |
| Flowability at −5°C — 30 min | ≥260 mm | — | ZRETE CBGM Antifreeze product data |
| Flowability at 8°C — initial | ≥300 mm | — | ZRETE CBGM Antifreeze product data |
| Flowability at 8°C — 30 min | ≥260 mm | — | ZRETE CBGM Antifreeze product data |
| Compressive strength — 1 / 3 / 7 days | ≥20 / ≥25 / ≥40 MPa | — | Published requirement |
| Compressive strength — 21 / 28 days | ≥60 / ≥90 MPa | — | Published requirement |
| 24-hour vertical expansion | 0.02–0.40% | — | Published requirement |
| 28-day restrained expansion — dry / water | ≤0.02% / ≤0.03% | — | Published requirement |
| Packaging / shelf life | — | Published value25 kg bags / 12 months | Unopened, dry storage |