Low-density offshore grout
CBGM-5 Low-Density Suction Bucket Foundation Grout
A low-density, non-shrink grout developed for suction bucket and suction caisson foundation installation where buoyancy, long flow retention and stable volume are critical.
Selection focus: suction bucket foundation grout
SINO-SINACBGM-5 Suction Bucket GroutVerified product main image pending
Recommended uses
Where this material fits.
- Offshore wind suction bucket foundations
- Suction caisson cavities and buoyancy zones
- Long-duration marine grouting operations
- Tidal installation conditions requiring stable flow
Performance benefits
What the system is designed to deliver.
- Low bulk density to reduce grout weight
- Flow retention up to eight hours
- Zero bleeding and zero 24-hour free shrinkage
- Continuous placement under long offshore installation cycles
Technical data
Published values for initial screening.
“Requirement” is the stated acceptance threshold or range. “Actual result”, “typical value” and “published value” are not guaranteed minima unless the requirement column says so. Final acceptance must follow the approved TDS, report, test method and project conditions.
Bulk density680–750 kg/m³
Apparent density1,300–1,500 kg/m³
Initial flowability≥290 mm
4-hour retained flow≥200 mm
8-hour retained flow≥150 mm
Packaging / shelf life25 kg; 12 months
Technical enquiry
Check whether CBGM-5 Suction Bucket Grout matches your project.
Include foundation type, grout geometry and volume, strength ages, flow requirement, temperature, standards, placement distance and equipment.